How to Program an Interlogix Networx NX4, NX6, or NX8 Tutorial – Alarm System Store

How to Program an Interlogix Networx NX4, NX6, or NX8 Tutorial – Alarm System Store


Hi. My name is Jason with alarmsystemstore.com. In today’s video, I’m going to be doing the
basic programming for the Interlogix NetworX panels. This video will apply to any of the network
systems, the NX4, NX 6, NX 8. They’re all basically the same. There will be some obvious slight changes
based on the number of zones and things like that. I’ll be following more or less what we have
in our Quickstart guide that we’ve written for you. And if you wait till the end of the video,
I’ll show you how you can get that. So, let’s go ahead and go to the table and
we’ll get started on the programming. All alright. So, I’ve got the system powered up. So, we’re all ready to go. First thing you’re gonna do is enter installer
programming. To do that, you’re gonna use *8 followed by
the installer code. The default installer code is 9713. After you enter that, it’s going to ask for
the device address, then pound. So, we’re going to use device address 0 and
then pound. And then you need a location followed by pound. So, the first thing we’re going to do is go
to location zero, which is for the phone number. So here, you’re just going to enter a fake
phone number pretty much. It doesn’t really matter what you enter here. You just want the system to dial out but it’s
not actually dialing to something directly, it’s just dialing to the bat. So, as long it dials out, we don’t care what
the number is. So, we’re going to just enter a 10-digit number
here, 1555555555. So, once you have entered the phone number
that you’re going to enter, you’ll just push pound. So, the next thing we need to do is enter
an account number, and this is device location 1. And again, the actual account number you entered
doesn’t matter, because it’s not what is really going to be used by the bat. So here, I’m just entering 1234, and then
pound. So, the next thing that we’ll do is go to
device location 2. And this is the reporting format. In here, you wanted to be on 13, it already
is. This is for contact ID, which is what you
wanna use for the bat unit. So, you’ll enter 13, and then star. So, that is all the programming that’s required. So, once you’ve completed the programming
and the wiring, you’re all done. So that now we know that we’re on a clean
slate here, first thing you wanna do is assign the keypad number and partition. And you wanna do this for all keypads. So to do that, you’re going to enter *94,
and then your installer code. So here, you’re going to enter the keypad
number. So, we’ll just make this keypad 1, and then
star, and then the partition number. And again, most people are just gonna do one
partition. In one, I can recover multiple partitions
on this video. It will be a lot of the same general steps
but there are slight differences. So again, we’re gonna assign this keypad partition
1, and then push star. All right. The next thing that we’re going to do is programming
the clock. And you can see, it doesn’t have any settings
yet for the clock. So instead of showing the time and date, it
actually says, “Set clock *97.” So, let’s go ahead and hit *97. It’s going to say, “Please enter your code.” And here, you’ll just use the master code,
default 1234. All right. Now you can see it says, “12:02 a.m.” Right now, it’s about 2:30 p.m. So, you can scroll through the hours. You can see it’s on 12 a.m. If we scroll down, it goes to 11 p.m. If you scroll up, it stays in the a.m., until
you go around again. So, we’ll just scroll to the 2, so, we’re
on 2:02 p.m., hit star, it goes to the minutes, which we’ll now scroll up to get to 30, star
again, it goes to the day. Today is Friday. It’s the 5th, and it is January, and the year
is ’18. Star again. And once you enter that all in, it automatically
exits back out. And so now, we’re gonna scroll in through
its screens, you can see Friday 2:30 p.m., January 5th. All right. So, now that we have a few basics done there,
let’s go ahead and go back into our main programming here which is *8, or by the installer code
which is 9713. All right. So it says, “Enter device address.” So, the majority of your programming is going
to be done on device address 0, and 0, basically, just means the main control panel. So, let’s go ahead and hit 0, and then pound. And then so now that we have the main control
panel selected, we just need to select the location within that. So, this is kinda like a programming field
or programming section, locations are kinda the same way. So the first thing that we’re going to do
is entry and exit delays, which is location 24. So, we’ll enter 24 and then pound. So now, we see location number 24, segment
number 1, and then it shows 30. So segment 1 corresponds to entry delay number
1. If we wanted to change it, we can. So, let’s say we wanted to make it a little
longer, say 45 seconds. So we do 45, and then star. When we push star, it goes to segment 2. Segment 2 is going to be for exit time 1. Let’s make exit time 1, 60 seconds. Yeah, exit time 1, 60 seconds, so it’s already
there, so we just hit star. Segment 3 is entry delay 2. Let’s make this one a little bit longer, and
we’ll say 60 seconds star, and then this is exit delay 2. We’ll keep it on 60 seconds as well. So 5 and 6 are not used, so you can just push
star, a couple of times to go through these, and then it exits back out and it says, “Enter
location.” So, next thing we’re going to program is zone
definitions for our hardwired zones. The location that you’ll use will vary depending
on the zone number. So, zones 1 through 8 are location 25, zones
9 through 16 are location 27, etc. There is more detail on this in our Quickstart
guide. For this example, we’re just gonna work with
location 25, so 125 and then pound. So now, it’s showing a segment 1, so location
25 segment 1, and it says, it’s a 3. So, this is the default that we have here. Some common zone definitions that we have
are 3, which we have here, which is entry exit delay 1, 9 which is entry exit delay
2, 5 is interior follower with auto bypass, so that’s kinda what you’d use for a motion
detector. Six is instant and it’s like a window contact,
things like that, 8 is for fire. If you’re using wireless zones, you’ll want
to use similar zone type definitions but they’ll have tamper as well. So, 17 corresponds to entry exit delay 1 with
tamper. Twenty is entry exit 2 with tamper. Eighteen is the interior follower with tamper,
and 19 is instant with tamper. So, those are some common ones and those are
all listed out in the Quickstart guide again, so you can go through, see those common ones. If you want a full list, you’ll wanna go to
the full installation manual for the NetworX panel. So, let’s go ahead and leave zone 1 on 3,
so I’ll just hit star here. Zone 2, we’ll say is our entry exit 2, so
we’ll hit 9 and then star, and so on. So now, we’re on segment 3 and we can set
these however we want. Change zone 4 to 5, which is interior follower,
etc. Once you’re finished programming all these,
if you’re not using them, you can enter 0. So, let’s say 7, 8 we’re not using. Once you have them all programmed, it goes
back to enter location. Now that we have our zone definitions done,
you can also turn zones on and off for various partitions. And these are kind of the work similarly to
our zone types. So location 26 is for zones 1 through 8, 28
is for 9 through 16, 30 is for 17 to 24, etc. Again, this is listed out in the Quickstart
guide, but just to show you an example. Let’s say on this system, we’re just using
our first two zones and we only have one partition. So, what we’ll do is we’ll enter 26, pound. And so, this is location 26, segment 1. Segment 1 corresponds to zone 1, and then
there’s toggle options down here. So you can see as I push numbers, they turn
on, as I push them again they turn off. Those are the partitions. So, if we wanted zone 1 partition 2, we can
turn 2 on, 1 off. If we wanna activate multiple partitions,
you put active in multiple partitions. That’s pretty much all you need to do to setup
a multiple partition system as far as the zones go. So, it’s pretty simple. For this example, again, most people, you
just need one partition. So, we’re gonna do zone 1 on in partition
1, push star, zone 2 on in partition 1 star. Now, zones 3 through 8, we’re not using. We can just turn those off. To do that, you just toggle the 1 off, so
there’s nothing there. So this zone is completely ignored for all
partitions. It’s star, and you do this again for each
zone, so there’s 7, there’s 8. Once you get down with 8, it goes back out. And you’d repeat this process depending on
the number of zones you’re using, generally turning them on, maybe turning them off, whatever
you need to do. Another thing that commonly people will want
to do is make sure that these panic buttons here on the side are active. It’s pretty easy to do. You’ll just go to location 23 and then you
wanna make sure that 5, 6, and 7 are on. So, we just have 5 on. So we’ll make sure 5, 6, 7 is on and so that’s
going to make sure that all three buttons are turned on. Once you have your numbers that you want on
on, you’ll just push star and that will save the changes that you made here. It will take you to segment 2, which is different
options but at this point you can just hit pound. Now, let’s go ahead and go back in, talk a
little bit more about it. So, segment 5 corresponds to the audible keypad
panic, and this is for the police. That’s kind of the basic one that most people
definitely want, which is why it’s on by default. Segment 6 enables the fire panic, and segments
7 enables the emergency, your medical is usually what it’s used for. So again, let’s say I didn’t want the medical,
I could turn that off. Maybe I just don’t want the fire, whatever
you wanna do. Once you have everything done, you hit star
to save and then pound to exit. The last thing I’m gonna show you as far as
basic programming goes, is how to turn resistors off. So, we always recommend using resistors on
a hardwired system, and aligned resistors are fairly easy to install. Generally, they can be done even if they’re
not already there. You can always add them in. They’re easy, like I said, to install and
they give you some peace of mind as far as the state of your wiring. We have a full video on resistors where I
go into great detail about what they actually do. But basically, for most of them is just going
to protect you from getting a short in the wire which will make, if you’re not using
the resistor, will make the zone look closed whether or not the door opens or closes, which
is obviously a problem, if you have the system alarms, somebody breaks in your front door
and the wire is shorted, you’re not gonna know. It’s not gonna trip the alarm. So, for residential cases, you know, it’s
not quite as important because there’s not gonna be as much opportunity for somebody
you don’t know or whatever, to tamper with the system. In businesses, you know, you almost definitely
wanna use it because there’s a good chance that somebody is going to be there that may
want to do that, a lot better chance, more opportunities. So, the way it works for the NetworX panels
is you actually have to turn on an option called the end-of-line resistor defeat. And you have to do this by zone type, so it’s
not by zone number for the network section by zone type. So, let’s say you have just two or three zone
types, you only have to go to those three zone types, turn on that option, and that
will essentially turn off resistors for your entire system. Or maybe it’s just your entry and exit doors
that you couldn’t get a resistor in there, so you just wanna go ahead and turn it off
for that. You can do that just by going to that zone
type, which is zone type three. There’s a location that corresponds to it,
and you can turn that option on. So, and that’s the example we’re going to
do for this. You’ll wanna refer to the manual for your
panels for all the different zone types. We don’t have them fully listed out, but basically
it’s going to be within locations 111 to 169 for most of the panels. So, zone type 3 corresponds to location 115. So, we’ll enter 115 and followed by pound. And so, you can see we’re on location 115
segment 1. We actually need to go to segment 4. So to do this, we just hit the asterisks or
the star key until we see segment number 4. So now, within here, we need to make sure
option 2 is on. To do that, you push 2, the 2 shows up. So now, resistor use is off for zone type
3. You’ll wanna hit star to save it, and then
you can hit pound to exit. Once you have that done, you’ve gone through
all the basic programming that’s required. There’s definitely other program sets that
may or may not need to be done. I will be doing a video on wireless zones
as well by itself, so if it’s not up already, it will be up soon, or we’ll have it linked
in the description as well. So once you’re done, you’ll just hit exit
a couple times and that will take you fully out of programming. One thing you’ll often see trouble conditions
type stuff pop up on the screen when you exit programming initially. This is completely normal, just give it about
30 seconds and then most of those will clear out. A lot of times it won’t clear out, in that
case, you definitely wanna do some troubleshooting, which we’ll also have a video on as well. Hi. For those of you that want the Quickstart
guide which we highly recommend, it makes it a lot easier. It’s kind of a step-by-step guide, very similar
to what we did in this video, even covers a little bit more than what I covered. To get to that, if you go to alarmsystemstore.com,
you’ll see the blue menu bar at the top, and you’ll go to resources. Under resources, you’ll see programming Quickstart
guides. If you follow that link, you’ll see a list
of the different manufacturers, and under the Interlogix, you’ll see the network’s panels. You click on that, it’ll pull it up on the
webpage and there’ll also be a link where you can download and print the guide. So, hopefully, you guys found this video really
helpful. If you did, make sure you hit the like button. Subscribe to our channel, we’re releasing
videos like this all the time. More people have subscribed, more likes we
get on videos, the more people we can reach about DIY security. So, thanks for helping us out. And as always, thanks for watching this video
and I’ll see you in the next one.

7 Replies to “How to Program an Interlogix Networx NX4, NX6, or NX8 Tutorial – Alarm System Store”

  1. Very informative. I’ve always used Honeywell Ademco equipment and I can almost program it in my sleep. The GE stuff is different and I’m still a bit confused on some of the programming but this video was very helpful. Thank you.

  2. is the features different in nx4 and nx 8? i have check the installer manual and it seems not the same. for example feature 25 are not the same

  3. Extraordinarily helpful! Any advice on how to change the 'welcome message' on the panel? Our panel still reads "Welcome to the (family who owned house before us) home." We would love to change it…

Leave a Reply